11 RC-80BZ Single Stage Heat/Cool Thermostat Installation Instructions DESCRIPTION The RC-80BZ is a precision digital thermostat designed for 24 VA
1100 04 Calibration offset This item is used to raise or lower the current temperature reading by 1 degree Fahrenheit or 1/2 degree Celsius. If this
1111 10 Heating anticipator This item adjusts the tendency of the thermostat to turn the heating unit off before the desired heat setting is reached.
1122 14 Clock adjust If the clock on the thermostat is running faster or slower than the actual time, you can have the thermostat automatically comp
1133 QUICK-REFERENCE SETUP GUIDE This table displays each Installer Setup item with its default setting. The column labeled "CURRENT" can
1144 The thermostat supports the following command classes: COMMAND_CLASS_THERMOSTAT_MODE COMMAND_CLASS_THERMOSTAT_SETPOINT COMMAND_CLASS_THERMOSTAT_
1155 COMMAND_CLASS_THERMOSTAT_OPERATING_STATE Upon power up, allow 10 seconds for the RC-80BZ thermostat to initialize. After 10 seconds, a controll
1166 TROUBLESHOOTING TIPS SYMPTOM ACTION TO TAKE 1. Check power to the thermostat 2. Check wiring diagrams Thermostat Dead 3. Check thermostat
22 Removing an existing thermostat 1. Disconnect the power to the control transformer. 2. Remove the cover to the existing thermostat. 3. Disconne
33 Connect each wire to the terminal strip on the thermostat base per the wiring diagram for your system application - See Figures 4 - 8. Form the
44 TYPICAL WIRING DIAGRAMS CAUTION: Be sure to disconnect the power to the control transformer before removing or installing thermostat. Do not sho
55 Common wire is required in “cool only” applications Figure 6 - Single stage cool only thermostat * Common wire is required to use the displ
66 *Do not connect RC and RH together. Figure 8 - Heating & cooling with separate transformers CONFIGURING THE BACKLIGHT ON THE RC-80ZB The
77 SOLDER WIRE JUMPER HERESELECT BACKLIGHTMODE (SET JUMPER)TO DISABLE KEYS LOCALLY Figure 9 POWER UP 1. Double check wiring, be sure that there
88 INSTALLER SETUP This section describes the items that the installer must setup as part of the thermostat installation. The Installer Setup mode i
99 00 Address If you are using Communications Mode 0 or 1, and you are installing more than one thermostat, each must be set to a consecutive addres
Commentaires sur ces manuels